Automated Actuator Testing System

Electrical Actuators
ITQ100 ~9000 Click here to view ITQ 0020 ~ 0080
 

Feature
Compact and robust construction, light weight providing high output torque
(Max 9000Nm).
Wide range of torque variation (From min 100Nm to max 9000Nm).
Hard anodized aluminum housing inside and outside with external powder coated
against severe industrial environment.
Enclosure using radial seals & O-rings that provide protection to waterproof IP67
(Nema 4 & 6) and optional watertight IP68
Mounting base according to ISO5211 standard.
Removable drive bushing for easy machining and mounting.
Self-locking provided by double worm gearing (no brake required).
Auto-declutching manual override handwheel with padlockable auto / manual switchable lever.
Reliable Mechanical Torque sensing system providing safe operation in overload condition.
Large size window and indicator provides better position indication from a distance.
Various Local position control options providing easy commissioning and operation in field.
Digitalized control component.
 
Technical Information  
Model ITQ 0100 ITQ
0160
ITQ
0240 
ITQ
0350 
ITQ
0500 
ITQ  0800 ITQ 1100  ITQ 2000  ITQ 3000  ITQ 6000  ITQ  9000
Rated torque(Nm) 100 160 240  350  500   800 1100  2000 3000 6000  9000
Duty Cycle S4(%) 40 30  30  30  30  30  30  30  30  30  30
Operating time(second)                      
50Hz 21 26  26  31  31  39  39 59 59  178  178
60Hz 18 22  22  26  26  32  32 50 50 149  149
Max bore Size(mm)                      
Key Φ 22 25  25  40  40  48  48  75  75 120 120
Square 20 23  23  34  34  40  40  64  64 100 100
Rated current(A)                      
1Phase/110V/50Hz 0.98 1.60  1.62  1.72  3.60  3.90 3.90        
60hz 1.10 1.70  1.72  1.80  3.90  4.20  4.30        
1Phase/220V/50Hz 0.52 0.85  0.87  0.92  1.50  2.05  2.15 2.95 3.75 2.95 3.75
60hz 0.58 0.90  0.90  0.95  1.60  2.20  2.30 3.15 3.85 3.15 3.85
3Phase/380V/50Hz 0.43 0.30  0.32  0.32  0.52  0.82  0.84 1.5 1.6 1.5 1.6
60hz 0.33 0.30  0.32  0.32  0.56  0.88  0.90 1.8 2.0 1.8 2.0
3Phase/4400V/50Hz 0.59 0.30  0.32  0.32  0.55  0.82  0.84 2.3 2.5 2.3 2.5
60hz 0.42  0.32  0.35  0.35  0.58  0.88  0.88 2.2 2.4 2.2 2.4
DC/24V 2.8  4.0  5.0 6.8   -  -  -  -  -  -  -
Motor insulation class F  F  F  F  F  F  F  F  F  F  F
ISO 5211 mounting flange F07  F07/
F10
 F07/
F10
 F/10
/F12
F10
/F12 
 F12
/F14
 F2/
F14
F16  F16  F25/
F30
 F25/
F30
Weight(Kg's) 7  15  15  20  20  25  25 42 42 152 152
No of handwheel turns 10  12  12  14  14  17  17 13 13 39 39
                       
   
Standard Specification
MODEL ITQ 100 ~ 3000
Enclosure Weatherproof IP67, NEMA4 & 6, O-ring sealed
Main Power Supply 110/220VAC/1Ph/50/60Hz, 380/440/VAC/3Ph/50/60/Hz±10%, 24VDC
Control Power Supply 110/220VAC/1Ph/50/60Hz ±10%
Duty Cycle (on-off) S2: 10Min~30Min
Duty Cycle (modulating) S4, 30~50%, 300~1200 start/Hour
Motor Squirrel Cage induction motor
Limit Switch 2 each for Open and Close (SPDT 250VAC/10A rating)
Torque Switches 1 each for Open and Close (SPDT 250VAC/10A rating except for ITQ 0100)
Stall protection/set temp. Built in thermal protection, open 150ºC±5ºC, close 97ºC±15ºC
Travel Angle 90º ±5º (0º ~ 100º)
Position Indicator Continuous mechanical indicator with arrow
Manual override De-clutchable
Self locking Provided by double worm gearing (no brake)
Mechanical stopper 1 each for each travel end (Open & Close), external & adjustable
Space Heater 5W(110/220VAC) for anti-condensation
Cable entries 2-PF 3/4” TAP
Lubrication EP type grease
Terminal block Screw and Lever Push type (spring loaded)
Ambient temperature Basic Actuator: -20º C~ +70ºC
c/w control options : -10ºC ~ +60ºC
Ambient Humidity 90% RH Max (Non-Condensing)
External Coating Dry Powder (Polyester)
   
Option Availability
Mechanical
Model Description Remark
EX Explosion proof(Ex d ll B T4) Approved by KTL
EX Watertight (IP68), Temporary submersible 10M Head 100hours
ALS Auxiliary limit switches (Max 2 for each travel end)  
ATS Auxiliary torque switches (Max 2 for each travel end) Except for ITQ 0100
EXT Extended travel angle(up to 120o, 135o, 180o, 270o) Except for ITQ with Gear box
SV Variation in torque and operating speed Please consult before ordering

Remote monitoring and control

PK Potentiometer kit (output signal : 0~1 Kohm)
High resolution potentiometer and precisely machined gearing
are directly engaged with drive shaft to feedback continuous position of valve
CT Current transmitter (output signal : 4-20mA)
Zero / Span Adjustment
Convertable DIP Switch (4 wire to 2 wire)
RPC/Signal Configuration Remote position controller (by input and output signal)
Input : 4-20mA, 0-10VDC, 2~10VDC, 1~5VDC, 0~5VDC
Output : 4-20mA, 0-10VDC, 2~10VDC, 1~5VDC, 0~5VDC
Auto-calibration
Reverse operating direction
Local Control

LP4 for 1 & 3 Phase (ITQ 0160~9000)

Control power : 110/220VAC, Option : 24VDC
Magnetic selector switches
Open/Close & Local/Stop/Remote

Local lamp indication

  • Power - White(on), Remote : Blue(on),
  • In case of Close Torque Switch Trip - Yellow(on) + Green(flickering)
  • In case of Open Torque Switch Trip - Yellow(on) + Red(flickering)
  • Full Close - Green(on), Closing - Green(flickering : only at Local Position)
  • Full Open - Red(on), Opening - Red(flickering : only at Local Position)
* Options Available : PK, CT, RPC(Modulating), IP68, Explosion proof

LM4 for 1 & 3 Phase (ITQ 0160~9000)

Including the same functions as LP4
Reversing electric contactors, Transformer

ICM1 for 1 & 3 Phase (Integral Control Module) (ITQ 0160~9000)

Main Power : 3Ph / 220/380/440 VAC
1Ph / 110/220 VAC
Control power : 24VDC, 5VDC

Magnetic selector switches
Open/Close & Local/Stop/Remote
Reversing electric contactors, Transformer, Phase Detector

Local lamp indication
  • Power - White(on), Remote : Blue(on),
  • In case of Close Torque Switch Trip - Yellow(on) + Green(flickering)
  • In case of Open Torque Switch Trip - Yellow(on) + Red(flickering)
    Full Close - Green(on), Closing - Green(flickering : only at Local Position)
  • Full Open - Red(on), Opening - Red(flickering : only at Local Position)

* Options Available : Explosion Proof, IP68
ICM2 for 1 & 3 phase (integral with LCD Display) (ITQ 0160~9000)
Including the same functions as ICM1

Enclosure : Reversing electric contactors, Transformer ,
Auto-Phase Discriminator, LCD Display
* Options Available : CT, RPC(Modulating), Explosion Proof,
IP68, Bus Communication



ICM3 for 1 & 3 phase (integral with LCD Display/IP68 Enclosure)
(ITQ 0160~9000)


Enclosure : Reversing electric contactors, Transformer ,
Auto-Phase Discriminator, LCD Display, IP68, Explosion Proof,
RPC(Modulating), Bus Communication
34pins seperate compartment for terminal block
BP for 1 Phase (ITQ 0100~0500)

Rechargeable Battery back up - Fail safe function
When Main power is alive, actuator works as normally.
Once power fails, actuator will move to pre-set fail safe position.
Input power : 110/220VAC, 50/60Hz
Output contacts : open/close/Alarm relay
LED signal indication : 4 LEDs (Full Open/Close, Over Torque and Power)
Rechargeable battery : 2.0AH 27.5VDC(Ni-Cd)